Structure, Codes and Safety

Structural systems, loads, concrete durability, building and fire codes and garage ventilation, explained. A Parkonomics glossary hub for parking structures.

Parking structures are unusual buildings. They are long, open to the weather, loaded by moving vehicles, and soaked every winter in de-icing salt carried in on tires. These terms cover how they are built to carry those loads and survive that exposure: the structural systems, the concrete and its reinforcement, and the joints that let the frame move.

They also cover the rules that govern them. Building and fire codes treat open and enclosed garages very differently, so openness, ventilation, construction type and sprinklers shape design long before the first column is drawn.

Start here

The Parkonomics view

Most garage problems that cost real money show up years after opening, in joints, drains and corroded steel. Durability is a design decision, and the cheapest time to make it is before the concrete is poured.

From Parkonomics

Every Structure, Codes and Safety term

73 terms

#

  • 1-Hour Fire ResistanceA 1-hour fire resistance rating means a wall, floor, beam or column assembly withstood 60 minutes of a standardized furnace fire, under ASTM E119...

A

  • Air OutletAn air outlet is the device at the end of a ventilation duct, such as a diffuser, grille or register, that delivers air into...
  • American Concrete Institute (ACI)The American Concrete Institute (ACI) is a technical and educational society that develops codes, specifications and guides for concrete design, construction and repair.
  • American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)ASHRAE, the American Society of Heating, Refrigerating and Air-Conditioning Engineers, is a professional society that develops standards and guidance for heating, ventilation, air conditioning,...
  • Authority Having Jurisdiction (AHJ)The authority having jurisdiction (AHJ) is the organization, office or individual responsible for enforcing a code or standard and approving equipment, materials, installations or...

B

  • Bituminous MaterialsBituminous materials are binders made from bitumen, the heavy residue of petroleum refining, or from coal tar, and they are the basis of asphalt...
  • Building CodeA building code is a set of minimum legal requirements for the design and construction of buildings, covering structure, fire safety, egress, accessibility, energy...

C

  • CantileverA cantilever is a structural member, such as a beam or slab, that is supported at only one end and projects freely past its...
  • Carbon Monoxide (CO)Carbon monoxide (CO) is a colorless, odorless gas produced by incomplete combustion. In parking garages it comes mostly from cold starts and idling gasoline...
  • CementCement is a fine powder, most commonly portland cement, that reacts with water to form the paste that binds sand and stone into concrete.
  • Chloride-Ion ContaminationChloride-ion contamination is the buildup of chloride ions inside concrete, mostly from deicing salts tracked in on vehicles or from marine air, that eventually...
  • Clear-Span Construction (Long-Span)Clear-span construction, also called long-span construction, is a parking structure framing approach in which the floor spans the full width of a parking module,...
  • Column CapitalA column capital is the enlarged, often flared, top of a column where it meets a concrete slab, used to spread the slab's load...
  • Computational Fluid Dynamics (CFD)Computational fluid dynamics (CFD) is the use of computer simulation to predict how fluids, such as air, smoke and heat, flow through and around...
  • Concentrated LoadA concentrated load is a force applied over a small area, such as a wheel, a jack, or a post, rather than spread evenly...
  • ConcreteConcrete is a building material made of portland cement or a blended binder, water, fine and coarse aggregates, and often chemical admixtures, which hardens...
  • Conventionally Reinforced ConcreteConventionally reinforced concrete is concrete strengthened with ordinary steel reinforcing bars (rebar) that are not tensioned, in contrast to prestressed systems such as post-tensioned...
  • Cubic Feet per Minute (CFM)Cubic feet per minute (CFM) is a unit of airflow: the volume of air, in cubic feet, that moves past a point each minute.

D

  • DeflectionDeflection is the amount a structural member, such as a beam, slab or double tee, bends or sags under load.
  • Demand-Controlled VentilationDemand-controlled ventilation (DCV) adjusts how much air a ventilation system moves based on measured conditions, rather than running at a fixed rate whenever the...

E

  • Enclosed Parking GarageAn enclosed parking garage is a parking structure that does not have enough exterior wall openings to qualify as an open parking garage, so...
  • Expansion JointAn expansion joint is a deliberate gap through a structure that divides it into independent sections, so each section can expand, contract and shift...
  • Exterior Insulation and Finish System (EIFS)An exterior insulation and finish system (EIFS) is a lightweight wall cladding made of rigid insulation board, a base coat reinforced with glass-fiber mesh,...

F

  • Factored LoadA factored load is a load multiplied by a load factor, so a structure designed to resist it carries a margin of safety against...
  • Fire Wall (Firewall)A fire wall is a fire-resistance-rated wall, continuous from the foundation to or through the roof, with enough structural stability that construction on either...
  • Floor DiaphragmA floor diaphragm is a floor or roof slab that acts as a horizontal beam, collecting lateral forces from wind or earthquakes and delivering...
  • Foundation SystemsA foundation system is the part of a structure that transfers its loads into the ground, through elements sized and selected for the soil...
  • Free-Standing Parking GarageA free-standing parking garage is a parking structure that stands on its own, rather than being built under, inside or wrapped by another building.

G

  • Group S-2 (Parking Garage Occupancy)Group S-2 is the low-hazard storage occupancy in the International Building Code. Parking garages, open or enclosed, fall in S-2 whether they have one...

H

  • HVACHVAC stands for heating, ventilation and air conditioning: the systems that control temperature, humidity and air quality in buildings.
  • Hybrid Concrete Structural SystemA hybrid concrete structural system combines precast and cast-in-place concrete in the same parking structure, using each where it works best.
  • Hybrid Steel SystemA hybrid steel system is a parking structure framing system that combines steel columns and beams with precast concrete double tees as the floor...

I

  • I-CodesThe I-Codes, or International Codes, are a family of model building and safety codes published by the International Code Council (ICC) and adopted, often...
  • International Building Code (IBC)The International Building Code (IBC) is a model building code published by the International Code Council (ICC) that sets minimum requirements for the design...
  • International Code Council (ICC)The International Code Council (ICC) is the nonprofit organization that develops the International Codes, or I-Codes, the model building and safety codes adopted by...
  • International Fire Code (IFC)The International Fire Code (IFC) is the model fire code published by the International Code Council and adopted, often with local amendments, by most...
  • International Mechanical Code (IMC)The International Mechanical Code (IMC) is the model code for mechanical systems, including heating, ventilation, air conditioning and exhaust, published by the International Code...
  • International Plumbing Code (IPC)The International Plumbing Code (IPC) is the model code for plumbing systems, including water supply, sanitary drainage, venting and fixtures, published by the International...

L

  • Lateral LoadsLateral loads are horizontal forces that push a structure sideways, as opposed to gravity loads that push down. The main sources are wind, earthquakes,...
  • Live Loads aka Live Design LoadsLive loads are the temporary, movable loads a structure must carry, such as vehicles, people, furniture and equipment, as distinct from dead loads, the...

M

  • Mechanical Ventilation SystemA mechanical ventilation system uses fans, and sometimes ductwork, to move fresh air through an enclosed parking garage and remove vehicle exhaust such as...
  • Moment Frames, Precast Moment FramesA moment frame is a structural system of beams and columns joined by rigid connections, so the frame resists sideways forces from wind and...

N

  • National Fire Protection Association (NFPA)The National Fire Protection Association (NFPA) is a U.S.-based nonprofit, founded in 1896, that develops and publishes consensus codes and standards for fire prevention,...
  • Natural VentilationNatural ventilation is the removal of vehicle exhaust and heat from a parking structure through openings in its exterior walls, using wind and air...
  • Nitrogen Dioxide (NO2)Nitrogen dioxide (NO2) is a reddish-brown, toxic gas formed when fuel burns at high temperature. In parking facilities, its main source is vehicle exhaust,...

O

  • Open Parking Garage (Open-Air Facility)An open parking garage, sometimes called an open-air parking facility, is a parking structure with enough uniformly distributed openings in its exterior walls on...
  • Openness CalculationThe openness calculation is the IBC test determining whether a parking structure qualifies as open: openings on each tier must total at least 20%...
  • OSHAThe Occupational Safety and Health Administration (OSHA) is the U.S. federal agency, created under the Occupational Safety and Health Act of 1970, that sets...
  • Out-of-Phase MovementOut-of-phase movement occurs when adjacent parts of a building, or adjacent buildings, move or vibrate in different directions or at different times during an...

P

  • Pan-joist SystemA pan-joist system is a one-way concrete floor made of closely spaced ribs, or joists, cast together with a thin top slab, formed by...
  • Post-Tensioned ConcretePost-tensioned (PT) concrete is concrete reinforced with high-strength steel tendons that are stressed after the concrete has hardened, putting the concrete into compression so...
  • Precast Pretensioned ConcretePrecast pretensioned concrete is concrete cast in a factory around high-strength steel strands that are stretched before the concrete is placed and released after...
  • Precast/Prestressed Concrete Institute (PCI)The Precast/Prestressed Concrete Institute (PCI) is the technical institute and trade association for the precast and prestressed concrete industry in North America. It publishes...

S

  • Seismic LoadsSeismic loads are the forces and deformations an earthquake imposes on a structure as the ground shakes beneath it. They depend on the expected...
  • Service LoadService load is the load a structure is expected to carry in normal use, combining its own weight (dead load) with the people, vehicles...
  • Shear WallA shear wall is a stiff vertical wall, usually reinforced concrete or masonry, that resists sideways forces from wind and earthquakes and carries them...
  • Short SpanIn parking structure design, short span describes a framing layout with interior columns placed within the parking bays, typically between groups of stalls, rather...
  • Smoke BarrierA smoke barrier is a continuous membrane, vertical or horizontal, such as a wall, floor or ceiling assembly, designed and constructed to restrict the...
  • Spalled (Spalling)Spalled describes concrete whose surface has cracked and broken away in fragments. In parking structures, spalling is most often caused by corrosion of reinforcing...
  • Sprinkler Design DensitySprinkler design density is the rate at which a sprinkler system must deliver water over a defined design area, expressed in gallons per minute...
  • Steel Bar Joist SystemsA steel bar joist system is a floor or roof system made of light, open-web steel joists spaced closely together, spanning between steel beams...
  • Structural Steel SystemA structural steel system is a parking structure framed with steel columns, beams and girders, with a concrete floor slab, cast-in-place or precast, spanning...
  • Structural Systems of ParkingIn the context of parking garage construction, structural systems refer to the frameworks and methodologies used to create the load-bearing components of the parking...
  • Subgrade MaterialSubgrade is the natural or improved soil on which a pavement is built, beneath the base course and the surface layer of asphalt or...

T

  • Type I ConstructionType I construction is the most fire-resistant classification in the International Building Code (IBC): structural elements, walls and floors are noncombustible, usually concrete or...
  • Type II ConstructionType II construction is a classification in the International Building Code (IBC) for buildings whose structural elements, walls and floors are made of noncombustible...

U

  • Ultimate LoadUltimate load is the load a structural member or system must be able to resist at the point of failure, calculated in strength design...
  • Uniform Building Code (UBC)The Uniform Building Code (UBC) was a model building code published by the International Conference of Building Officials (ICBO) and widely adopted in the...

V

  • Variable Frequency Drive (VFD)A variable frequency drive (VFD) controls motor speed by varying power frequency. In parking garages, VFDs paired with CO sensors can cut ventilation fan...
  • Vertical ClearanceVertical clearance is the height from the floor to the lowest overhead obstruction in a parking facility, such as a beam, pipe, sprinkler, light,...
  • Volatile Organic Compounds (VOCs)Volatile organic compounds (VOCs) are carbon-based chemicals that evaporate readily at normal temperatures, releasing gases that can affect health and contribute to ground-level ozone,...

W

  • Waffle Slab Floor SystemA waffle slab is a two-way reinforced concrete floor system made with a grid of ribs, formed by placing square dome forms on the...
  • Wind LoadsWind loads are the pressures and forces that wind exerts on a structure and its components. In the United States they are calculated under...

Other topics

Browse the full glossary, A to Z